FreshRSS

🔒
❌ Acerca de FreshRSS
Hay nuevos artículos disponibles. Pincha para refrescar la página.
AnteayerTus fuentes RSS

Sociological determinants of adherence to continuous positive airway pressure in the management of sleep apnoea syndrome: protocol for a transdisciplinary, prospective observational study

Por: Bailly · S. · Foote · A. · Mendelson · M. · Rakotovao · A. · Borel · J. C. · Pepin · J. L. · Tamisier · R. · Revil · H.
Introduction

Obstructive sleep apnoea syndrome (OSAS) is a chronic multiorgan pathology that has a negative impact on quality of life. Continuous positive airway pressure (CPAP) is the first-line treatment for OSAS. However, CPAP termination rates remain very high, and adherence to therapy is a major issue. To date, studies targeting predictive factors of CPAP adherence by OSAS patients mainly include clinical data. The social, socioeconomic, psychological, and home environment aspects have been far less studied and largely underestimated. This study aims to obtain solid quantitative results examining the relationship between the determinants of refusal, non-adherence, or termination of CPAP treatment, and in particular the pivotal role played by health literacy.

Methods and analysis

This is a prospective, multicentre, observational study recruiting patients attending the sleep clinic of the Grenoble Alpes University Hospital, France. Consecutive adults (>18 years) recently diagnosed with OSAS and prescribed CPAP treatment with telemonitoring will be enrolled in the present study. They will benefit from home visits by a CPAP technician or nurse at CPAP initiation. Patients will then be followed up for 6 months through the telemonitoring platform of a home-care provider. The primary objective is to evaluate the impact of health literacy (health literacy, measured by the European Health Literacy Survey questionnaire (HLS-EU-16) on the refusal, non-adherence or termination of CPAP treatment in newly diagnosed OSAS patients, during the first 6 months after diagnosis. The target sample size is 250 participants.

Ethics and dissemination

The study protocol, patient information, and the non-opposition form were approved by the French national ethics committee (CPP 2021-92, January 2022). All patients are required to have signed a written informed consent form permitting their anonymised personal and medical data to be used for clinical research purposes. We will publish the results in a peer-reviewed medical journal and on our institutional websites.

Trial registration number

NCT05385302.

Invasive device‐associated skin complications and mechanical dysfunctions in paediatric healthcare: A systematic review and meta‐analysis

Abstract

Aim

This study aimed to estimate the proportion and rate of skin complications and mechanical dysfunction associated with indwelling invasive devices in paediatric healthcare.

Design

This systematic review is reported in accordance with Cochrane standards for randomized controlled trials and the Meta-analysis of Observation Studies in Epidemiology for cohort studies.

Data Sources

MEDLINE, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched.

Review Methods

Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) paediatric participants admitted to a hospital, (3) reporting post-insertion device-associated skin complication and/or mechanical dysfunction, and (4) published in English, were included. Device-associated skin complication and mechanical dysfunction (infiltration, leakage, occlusion/blockage, dislodgement/malposition, breakage and others). Pooled proportion and incidence rate per 1000 device days are reported.

Results

This review synthesized 114 studies (30,782 devices; 1,635,649 device-days). Skin complications were reported in 40 studies, but none exclusively reported individual device-related pressure injuries. Mechanical dysfunctions were well-reported for central venous access devices, peripheral intravenous catheters, nasogastric/gastric tubes and peritoneal dialysis catheters but less for arterial catheters, extracorporeal membrane oxygenation and ventricular assist devices.

Conclusions

This systematic review highlights the need for standardized definitions and reporting methods to better surveil and benchmark device-related complications, particularly for understudied device types. Device-related pressure injuries were not reported in any of the included studies, and all devices except for vascular access devices require standardized reporting of complications.

Impact

Despite the widespread use of invasive devices, comprehensive data on their prevalence, utility, and associated paediatric complications is limited. This review identified prevalent skin complications, occlusions and dislodgments in children with devices, underscoring the need for standardized reporting to enhance surveillance and understanding of paediatric device-related complications.

Reporting Method

MOOSE (Meta-analyses Of Observational Studies in Epidemiology) Checklist.

Patient or Public Contribution

No Patient or Public Contribution.

The other COVID‐19 survivors: Timing, duration, and health impact of post‐acute sequelae of SARS‐CoV‐2 infection

Abstract

Aims and Objectives

To determine the frequency, timing, and duration of post-acute sequelae of SARS-CoV-2 infection (PASC) and their impact on health and function.

Background

Post-acute sequelae of SARS-CoV-2 infection is an emerging major public health problem that is poorly understood and has no current treatment or cure. PASC is a new syndrome that has yet to be fully clinically characterised.

Design

Descriptive cross-sectional survey (n = 5163) was conducted from online COVID-19 survivor support groups who reported symptoms for more than 21 days following SARS-CoV-2 infection.

Methods

Participants reported background demographics and the date and method of their covid diagnosis, as well as all symptoms experienced since onset of covid in terms of the symptom start date, duration, and Likert scales measuring three symptom-specific health impacts: pain and discomfort, work impairment, and social impairment. Descriptive statistics and measures of central tendencies were computed for participant demographics and symptom data.

Results

Participants reported experiencing a mean of 21 symptoms (range 1–93); fatigue (79.0%), headache (55.3%), shortness of breath (55.3%) and difficulty concentrating (53.6%) were the most common. Symptoms often remitted and relapsed for extended periods of time (duration M = 112 days), longest lasting symptoms included the inability to exercise (M = 106.5 days), fatigue (M = 101.7 days) and difficulty concentrating, associated with memory impairment (M = 101.1 days). Participants reported extreme pressure at the base of the head, syncope, sharp or sudden chest pain, and “brain pressure” among the most distressing and impacting daily life.

Conclusions

Post-acute sequelae of SARS-CoV-2 infection can be characterised by a wide range of symptoms, many of which cause moderate-to-severe distress and can hinder survivors' overall well-being.

Relevance to Clinical Practice

This study advances our understanding of the symptoms of PASC and their health impacts.

Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An <i>in vitro</i> study

by Priscila Ceolin Meneghetti, Junying Li, Paulo Sérgio Borella, Gustavo Mendonça, Luiz Henrique Burnett Jr

This study aimed to compare the accuracy of full-arch digital implant impressions using seven different scanbodies and four intraoral scanners. A 3D-printed maxillary model with six implants and their respective multi-unit abutments was used for this study. Seven scanbodies (SB1, SB2, SB3, SB4, SB5, SB6, and SB7) and four intraoral scanners (Primescan®, Omnican®, Trios 3®, and Trios 4®) were assessed. Each combination group was scanned ten times and a dental lab scanner (D2000, 3Shape) was used as a reference. All scans were exported as STL files, imported into Convince software (3Shape) for alignment, and later into Blender software, where their 3D positions were analyzed using a Python script. The 3D deviation, angular deviation, and linear distance between implants #3 and #14 were also measured. Accuracy was measured in terms of “trueness” (scanbody 3D deviation between intraoral scan and desktop scan). Kruskal-Wallis followed by the Bonferroni correction was used to analyze the data (⍺ = .05). The study found statistically significant differences in digital impression accuracy among the scanners and scanbodies (p
❌